1000W – 12000W 12V/24V/48V AC One Stage Off Grid Hybrid Solar Power Panel Inverter
With trustworthy clever layout,GS series photo voltaic inverter can be avaiilable to complicated appliance. Not only used for widespread appliances these kinds of as Television,computwe,lights,enthusiasts…but also appropriate for inductive loading this kind of as refrigerators,airconditioners,motors,pumps,compressors and laser printers.
♦ GS Sequence AC/Photo voltaic charging Off grid Hybrid Inverter.
♦ LED/Lcd exhibit, Enhanced features location through Liquid crystal display, Male-machine clever layout.
♦ Created-in 40A/60A optional MPPT photo voltaic charger controller.
♦ Liquid crystal display shows the solar ability.
♦ 5 phases adjustable AC charging existing. AC charging also can be closed.
♦ AC/DC precedence modes can be set.
♦ Generator restart signal. (Dry contact)
♦ 3 instances peak electricity. Sturdy loading capacity.
♦ Overload, output limited-circuit defense.
Model Parameters | GS1000W | GS2000W | GS2500W | GS3000W | |
AC Input |
Nominal Power | 1000W | 2000W | 2500W | 3000W |
Input Voltage Waveform | Sinusoidal (utility or generator) | ||||
Nominal input Voltage | one hundred twenty/230VAC | ||||
Minimal Line Disconnect | 85Vac±4%(Typical) or 80Vac±4% (Vast) for 120V 184Vac±4%(Standard) or 135Vac±4%(Extensive) for 230V | ||||
High Line Disconnect | 136Vac±4%(Standard) or 140Vac±4%(Broad) for 120V 263Vac±4%(Normal) or 263Vac±4%(Vast) for 230V | ||||
Max AC input Voltage | 120V for Max150V, 230V for Max270V | ||||
Frequency | 50Hz:41-54Hz, 60Hz:51-64Hz | ||||
AC output |
Output Voltage Waveform | Sine wave | |||
Electricity Factor | .9~1. | ||||
Nominal Output Voltage (V) | LV:120Vac ±10%rms, HV:230Vac ±10%rms | ||||
Nominal Output Frequency (Hz) |
50Hz ± .3Hz, 50Hz ± .3Hz | ||||
Photo voltaic charger |
Rated Charge Existing | 40A | 60A | ||
PV Input Voltage selection | 15VDC-40VDC for 12VDC, 30VDC-55VDC for 24VDC, sixty-110VDC for 48V | ||||
Max.PV open up circuit array voltage |
12V for 40Vdc, 24V for 55Vdc, 48V for 110Vdc | ||||
Charger method | MPPT | ||||
PV Lower Voltage Re-join |
PV≥Bat.V+3V | ||||
PV Low Voltage Disconnect |
PV<=Bat.V | ||||
Efficiency | ≥97% | ||||
AC Charger |
Nominal Charger Existing |
35A/50A/70A/90A(In accordance to the inverter product) | |||
five levels adjustable charging existing | |||||
More than charge Safety | Bat.V≥15.5VDC for 12V battery, Bat.V≥31.0VDC for 24V battery ,Bat.V≥62.0VDC for 48V battery beeps .5s each 1s & fault soon after 60s | ||||
Performance | Effectiveness(Battery Mode) | ≥87% | |||
Efficiency (Line Method) | >98% | ||||
Battery Voltage |
Nominal DC input Voltage | twelve/24/48VDC | |||
Low Battery Alarm | 10.5VDC±0.3VDC for 12VDC | ||||
21VDC±0.6VDC for 24VDC | |||||
42VDC±1.2VDC for 48VDC | |||||
High DC enter Alarm & Fault |
16VDC±0.3VDC for 12VDC | ||||
32VDC±0.6VDC for 24VDC | |||||
64VDC±1.2VDC for 48VDC | |||||
Transfer Time |
20ms(max) | ||||
Program Parameter |
Over-Load Defense | a hundred and ten%<load<150%, beeps 0.5s every 1s, and Fault after 60s off the output,load>150%, beeps .5s every 1s, and Fault right after 20s |
|||
Output Short Circuit Protection |
Recent restrict (Fault after 10s) | ||||
Surge Rating(10s) | 1:three(VA) | ||||
Electrical power Saver | Load≤25W(Enabled on “P/S auto”Setting of Distant control) | ||||
Protections | Low battery, more than charging, in excess of load, over temp | ||||
CZPT Specifications |
Functioning Temperature Assortment |
0ºC~40ºC | |||
Storage Temperature | -15ºC~60ºC | ||||
Procedure humidity | 5% to ninety five%(non-condensing) | ||||
Audible Noise | 60dB max | ||||
cooling | Forced air,variable speed admirer | ||||
Dimension(L*W*H) | 480*336*190mm | ||||
Internet Excess weight(kg) | 19.five | 23.five | 25.five | 28 |
Parameters Design | GS4000W | GS5000W | GS6000W | GS7000W | GS8000W | GS10KW | |
AC Enter |
Nominal Electrical power | 4000W | 5000W | 6000W | 7000W | 8000W | 10KW |
Enter Voltage Waveform | Sinusoidal (utility or generator) | ||||||
Nominal enter Voltage | 120/230VAC | 230VAC | |||||
Minimal Line Disconnect | 85Vac±4%(Standard) or 80Vac±4% (Vast) for 120V / 184Vac±4%(Typical) or 135Vac±4%(Extensive) for 230V | ||||||
Lower Line Re-link | 95Vac±4%(Normal) or 85Vac±4% (Wide) for 120V / 194Vac±4%(Regular) or 145Vac±4%(Vast) for 230V | ||||||
Higher Line Disconnect | 136Vac±4%(Regular) or 140Vac±4%(Extensive) for 120V / 263Vac±4%(Standard) or 263Vac±4%(Extensive) for 230V | ||||||
Substantial Line Re-link | 131Vac±4%(Regular) or 135Vac±4% (Vast) for 120V / 253Vac±4%(Regular) or 253Vac±4%(Extensive) for 230V | ||||||
Max AC enter Voltage | 120V for Max150V | 230V for Max270V | |||||
Frequency | 50Hz:41-54Hz / 60Hz:fifty one-64Hz | ||||||
AC output |
Output Voltage Waveform | Sine wave | |||||
Electricity Factor | .nine~1. | ||||||
Nominal Output Voltage (V) | LV:120Vac ±10%rms / HV:230Vac ±10%rms | HV:230Vac ±10%rms | |||||
Nominal Output Frequency (Hz) |
60Hz ± .3Hz 50Hz ± .3Hz | ||||||
Solar charger |
Rated Demand Present | 60A | |||||
PV Input Voltage range | 30VDC-55VDC for 24VDC / 60-110VDC for 48V | ||||||
Max.PV open circuit array voltage |
24V for 55Vdc / 48V for 110Vdc | ||||||
Charger manner | MPPT | ||||||
PV Low Voltage Re-hook up |
PV≥Bat.V+3V | ||||||
PV Low Voltage Disconnect |
PV<=Bat.V | ||||||
Efficiency | ≥97% | ||||||
AC Charger |
Nominal Charger Recent |
35A/50A/70A(In accordance to the inverter product) | |||||
five stages adjustable charging current | |||||||
Above charge Safety | Bat.V≥31.0VDC for 24V battery ,Bat.V≥62.0VDC for 48V battery beeps .5s each and every 1s & fault soon after 60s | ||||||
3-phase charging | A few stage:Increase cc (continuous current phase) | ||||||
Enhance CV (continual voltage stage) | |||||||
float (conatant voltage phase) | |||||||
Performance | Efficiency(Battery Manner) | ≥87% | |||||
Effectiveness (Line Method) | >98% | ||||||
Battery Voltage |
Nominal DC input Voltage | 24/48VDC | 48VDC | ||||
Minimal Battery Alarm | 21VDC±0.6VDC for 24VDC | ||||||
42VDC±1.2VDC for 48VDC | |||||||
Low DC input shut-down | 20VDC±0.6VDC for 24VDC | ||||||
40VDC±1.2VDC for 48VDC | |||||||
Higher DC input Alarm & Fault |
32VDC±0.6VDC for 24VDC | ||||||
64VDC±1.2VDC for 48VDC | |||||||
High DC enter CZPTvery |
31VDC±0.6VDC for 24VDC | ||||||
62VDC±1.2VDC for 48VDC | |||||||
Transfer Time |
AC to DC | 20ms(max) | |||||
DC to AC | 15ms(max) | ||||||
Method Parameter |
More than-Load Defense | a hundred and ten%<load<150%,beeps 0.5s every 1s,and Fault after 60s off the output,load>150%,beeps .5s each and every 1s,and Fault soon after 20s |
|||||
Output Brief Circuit Security |
Current restrict (Fault following 10s) | ||||||
Surge Rating(10s) | 1:3(VA) | ||||||
Electricity Saver | Load≤25W(Enabled on “P/S vehicle”Location of Remote manage) | ||||||
Protections | Reduced battery, more than charging, above load, more than temp | ||||||
Indicators | LED+Lcd Screen | ||||||
CZPT Requirements |
Running Temperature Assortment |
0ºC to 40ºC | |||||
Storage Temperature | 15ºC~60ºC | ||||||
Procedure humidity | five% to 95%(non-condensing) | ||||||
Audible Noise | 60dB max | ||||||
cooling | Forced air,variable speed supporter | ||||||
Dimension(L*W*H) | 530*400*190mm | 627*416*204mm | |||||
Web Bodyweight(kg) | 30.0kg | 35.5kg | 38.5kg | forty one.5kg | forty eight.0kg | fifty five.0kg |
Our Organization:
HangCZPT ZLPOWER CZPT Co., Ltd proven on 2006 a long time. We are national large-tech enterprise which skilled studying, manufacturing and exporting UPS power offer, Inverter electricity supply, Solar inverter, Automobile charging pile, EPS electricity provide. Our electricity goods potential from 400VA to 400KVA parallel series parallel collection, which can satisfy distinct fields clients specifications.
ZLPOWER Business had handed ISO 9001, ISO 14001 and our items had handed Thayer certification, CE certification, UL certification, ETL certification, CCC certification……Our merchandise are sold all more than the world, mostly exported nations and locations incorporate CZPTpe, Africa, Center East, Asia, United states of america, Canada…Our products widely utilized for army, finance, interaction, health care therapy, market, general public safety and civil electricity answers.
Why pick us:
one.Far more than eleven a long time knowledge in the discipline of UPS electrical power provide and Solar power program.
2.Our skilled R&D team enables us to develop CZPT product strains for clients.
3.Totally free OEM Support, Quickly Lead Time seven-30 times, Higher Top quality (CE&ISO)
four. Excellent high quality and aggressive cost.
FAQ:
Q1. How to choose the right Inverter?
one. Comprehend technical specs of all inverter.
2. Take into account the requirements of energy top quality.
three. Comprehend the recent potential of inverter and consider the future growing.
4. Select inverter primarily based on your concrete needs.
Q2. What are critical variables you ought to think about when buying inverter?
1. inverter’s dependability and balance.
2. The outstanding engineers and the capacity of items creation.
three. Substantial performance and minimal sound.
four. Supplier’s reputation and fiscal circumstance.
five. CZPT security certification this sort of as UL, CCC, etc.
6. Plant certifications such as CZPT, ISO14001, and so forth.
Q3.How about our provider?
As a user of ZLPOWER, you have the following provider:
one. Two many years warranty (covering batteries purchased from ZLPOWER)
two. 24-hour helpline Services helpline: -755-29105850
3. Nationwide warranty
four. CZPT assist on our site: